Scutti srl
Scutti srl
Italiano
English

Specialist in cement and lime storage

WICOMSILO SAFETY SYSTEM

Filling a powders storage silo is always a critical operation because the air pressure can rise inside it at such a rate that it could put at risk the silo’s integrity.

WICOMSILO is a safety system which use a series of devices to prevent a dangerous build-up of internal pressure, such as would threaten the structure of the silo and the safety of anyone in the vicinity.

Smasrtsilo Safety Sysem

1

The WICOM control box checks the air pressure into the silo and interacts with the several safety devices.
Smasrtsilo Safety Sysem

2

The MS pneumatic hose is located on the silo’s roof to connect WICOM control box to the inside of the silo.
Smasrtsilo Safety Sysem

3

The de-dusting filter unit MAXAIR-24, is designed to collect and release into the silo the powder rising during the silo’s filling. OPTIONAL
Smasrtsilo Safety Sysem

4

The VDS/273 is a pressure relief valve safety device which automatically opens in case of the internal pressure exceeds the design rate.
Smasrtsilo Safety Sysem

5

The RLB level indicator, detects and displays via a lamp that the product has reached the maximum level in the silo.
Smasrtsilo Safety Sysem

6

The SA siren, is a safety device which gives an acoustic warning at any anomaly in the safety system.
Smasrtsilo Safety Sysem

7

VISUAL is a touch screen PLC which controls the WICOM control box, locally or via remote access. Available in two sizes display: 4 or 7 inches.
Smasrtsilo Safety Sysem

8

VL pinch valve, designed to close the fill line in case of emergency. Available in two sizes: DN80 and DN100.
Smasrtsilo Safety Sysem

9

The PN pneumatic box contains the fittings to connect the pinch valve and the AIR pressure switch.
Smasrtsilo Safety Sysem

10/A

The E-100 adaptor ensures the connection between the tank lorry and the silo’s fill pipe via a STORZ coupling. Available in two sizes: DN80 and DN100.
Smasrtsilo Safety Sysem

10/B

The IT-100 adaptor ensures the connection between the tank lorry and the silo’s fill pipe via a PIN coupling. Available in two sizes: DN80 and DN100.
Smasrtsilo Safety Sysem

11

The CM terminal box collects all the cables coming from the devices and connects to the WICOM control box via ONE cable only.
Smartsilo Safery System